Ensure that the following tools are to hand:

q

Torx® 25

q

Torx® 15

q

Screwdriver

q

Battery-powered screwdriver, if necessary

q

Second person for fitting work, if needed

4.3.1 Detaching the door

Note

u

Remove any food from the door racks before removing the

door, so that no food falls out.

Fig. 4

u

Close the door.

u

Pull off the cover

Fig. 4 (10)

forwards and upwards.

u

Lift off the cover

Fig. 4 (11)

.

CAUTION

Risk of injury if the door tips!

u

Take good hold of the door.

u

Set down the door carefully.

u

Unscrew the upper turn hinge

Fig. 4 (12)

(2x Torx® 25)

Fig. 4 (13)

and lift it off.

u

Lift off the door and set it aside.

4.3.2 Changing the bearing parts

Fig. 5

u

Lift out the bearing pin

Fig. 5 (22)

together with washer

Fig. 5 (23)

and adjustable-height foot

Fig. 5 (24)

.

u

Lift off the stopper

Fig. 5 (21)

.

u

Unscrew

Fig. 5 (26)

the turn hinge

Fig. 5 (25)

.

u

Unscrew

Fig. 5 (29)

the bearing element

Fig. 5 (28)

, transfer

it to the opposite location hole of the turn hinge and screw it

firmly into place.

u

Carefully lift off the cover on the handle side

Fig. 5 (27)

and

transfer it to the opposite side.

u

Screw the turn hinge

Fig. 5 (25)

firmly into place on the new

hinge side, possibly using a cordless screwdriver (with

4 Nm).

u

Re-insert the stopper

Fig. 5 (21)

into the other hole.

u

Re-insert the bearing pin

Fig. 5 (22)

together with the

washer and adjustable-height foot. In so doing, pay attention

that the locating lug points backwards

4.3.3 Transferring the handle

u

Transfer the spring clamp

Fig. 6 (31)

: Depress the

latch nose and pull the

spring clamp off over it.

u

Slide the spring clamp

into place on the new

hinge side until it clicks

into place.

Fig. 6

Fig. 7

u

Lift the stopper

Fig. 7 (33)

out of the door bearing bush and

transfer it.

u

Dismantle the door handle

Fig. 7 (32)

, stoppers

Fig. 7 (33)

and pressure plates*

Fig. 7 (34)

and transfer to the opposite

side.

u

When fitting the pressure plates on the opposite side, make

sure they snap properly into place.*

4.3.4 Fitting the door

u

Place the door from above onto the lower bearing pin

Fig. 5 (22)

.

u

Close the door.

u

Insert the upper turn hinge

Fig. 4 (12)

in the door on the new

hinge side.

u

Screw the upper turn hinge

Fig. 4 (12)

firmly into place (with

4 Nm)(2x Torx® 25)

Fig. 4 (13)

. Possibly make preliminary

holes with a bradawl or use a cordless screwdriver.

u

Snap the cover

Fig. 4 (10)

and cover

Fig. 4 (11)

into place at

the opposite side.

4.3.5 Aligning the door

u

Align the door to the appliance housing by way of the two

oblong holes in the bottom turn hinge

Fig. 5 (25)

. To do so,

unscrew the middle screw.

Putting into operation

6

* Depending on model and options