Setting up, Electrical requirement, Fitting dimensions (mm) – Liebherr WTUes 1653 Vinidor User Manual
Page 4: Installation and fitting
Setting up
• Avoid locating the appliance it in direct sunlight or near heat sources such as an oven
or a radiator.
• The floor should be level and even. You can compensate for an uneven floor by ad-
justing the adjustable feet.
• Standard EN 378 specifies that the room in which you install your appliance must
have a volume of 1 m
3
per 8 g of R 600a refrigerant used in the appliance, so as to
avoid the formation of inflammable gas/air mixtures in the room where the appliance
is located in the event of a leak in the refrigerant circuit. The quantity of refrigerant
used in your appliance is indicated on the type plate on the inside of the appliance.
• The appliance is set to operate within specific ambient temperature limits according
to its climate rating. These temperature limits should not be exceeded. The correct
climate rating for your appliance is indicated on the type plate.
SN = +10°C to +32°C
SN - ST = +10°C to +38°C
Electrical requirement
Power supply (AC) and voltage at the operating point must comply with the details
on the type plate. The socket must be fused with a 10 A fuse or higher, it must be away
from the rear of the appliance and must be easily accessible.
16
Fitting dimensions (mm)
• Adjust to recess height using the 4 adjus-
table feet on the underside of the appli-
ance.
• Connect the appliance to the mains.
• Slide the appliance into the recess.
• Secure the appliance in the recess
using 4 x 14 screws.
Installation and fitting
The ventilation cross-section in the plinth panel must be min. 300 cm².