beautypg.com

4putting into operation, 1transporting the appliance, 2installing the appliance – Liebherr GN 4113 Comfort NoFrost User Manual

Page 5: 3changing over the door hinges, 4 putting into operation, Putting into operation, 1 transporting the appliance, 2 installing the appliance, 3 changing over the door hinges

background image

4 Putting into operation

4.1 Transporting the appliance

CAUTION

Risk of injury and danger of damage as a result of incorrect

transport!

u

Transport the appliance in a packed condition.

u

Transport the appliance upright.

u

Do not transport the appliance without assistance.

4.2 Installing the appliance

WARNING

Fire hazard due to dampness!

If live parts or the mains lead become damp this may cause

short circuits.

u

The appliance is designed for use in enclosed areas. Do not

operate the appliance outdoors or in areas where it is

exposed to splash water or damp conditions.

WARNING

Risk of fire due to short circuit!

If the mains cable/connector of the appliance or of another

appliance touch the rear of the appliance, the mains cable/

connector may be damaged by the appliance vibrations,

leading to a short circuit.

u

Stand the appliance so that it is not touched by connectors

or main cables.

u

Do not plug the appliance or any others into sockets located

near the rear of the appliance.

WARNING

Fire hazard due to refrigerant!

The refrigerant R 600a is environmentally friendly but flam-

mable. Escaping refrigerant may ignite.

u

Do not damage the piping of the refrigeration circuit.

WARNING

Fire hazard and danger of damage!

u

Do not place appliances emitting heat e.g. microwaves,

toasters etc. on the appliance!

WARNING

Blocked ventilation openings pose a risk of fire and damage!

u

Always keep the ventilation openings clear. Always ensure

that the appliance is properly ventilated!

NOTICE

Risk of damage due to condensate!

u

Do not install the appliance directly alongside a further

refrigerator/freezer.

q

In the event that the appliance is damaged, contact the

supplier immediately before connecting to the mains.

q

The floor at the site must be flat and level.

q

Do not install the appliance in a location where it is exposed

to direct radiation of the sun, next to a cooker, heater and

similar.

q

The ideal installation site is a dry, well ventilated room.

q

Always stand the appliance backed directly to the wall using

the enclosed wall spacers (see below).

q

The appliance may be moved only when it is empty.

q

Do not install the appliance without assistance.

q

The more R 600a refrigerant there is in the appliance, the

larger the room in which the appliance is standing needs to

be. In rooms that are too small, a flammable mix of gas and

air may be created if there is a leak. According to the EN

378 standard, every 11 g of R 600a refrigerant requires at

least 1 m

3

space in the room for the appliance. The amount

of refrigerant in your appliance is on the type plate inside the

appliance.

u

Detach the connecting cable from the rear of the appliance,

removing the cable holder at the same time because other-

wise there will be vibratory noise!

u

Remove the protective film from the decorative trims.

u

Remove all transit supports.

The spacers supplied with some appliances must be used to

achieve the stated energy consumption. These will extend the

depth of the appliance by approx. 35 mm. The appliance is fully

functional if the spacers are not used, but does have a slightly

higher energy consumption.

u

In the case of an appliance with

enclosed wall spacers, mount the

wall spacers on the back of the

appliance at the top left and right.

u

Dispose of packaging material (see 4.5) .

u

Align the appliance so that it

stands firmly and on a level by

applying the accompanying

spanner to the adjustable-

height feet (A) and using a

spirit level.

Note

u

Clean the appliance (see 6.2) .

If the appliance is installed in a very damp environment,

condensate may form on the outside of the appliance.

u

Always see to good ventilation at the installation site.

4.3 Changing over the door hinges

You can change over the door hinges if necessary.
Ensure that the following tools are to hand:

q

Torx 25

q

Torx 15

q

Open-ended spanner size 6

q

Screwdriver

q

Open-ended spanner included in supply package

q

Second person for fitting work, if needed