8. INSTALLATION

8.1 Mains voltage

Before connecting the unit to the mains, please make

sure that the voltage setting on the unit matches the

local voltage! The fuse holder at the AC power connector has

3 triangular markings. Two of these three triangles are aligned

with one another. The unit is set to the voltage shown next to

these markings and can be switched over by turning the fuse

holder by 180°. IMPORTANT: This does not apply to export

models designed exclusively for 120 V operation!

+

If you set the unit to a different mains voltage, be

sure to use a fuse of the correct type and rating.

Please refer to chapter 9 “SPECIFICATIONS” for

details.

+

Blown fuses must be replaced by fuses of the same

type and rating! Please refer to chapter 9

“SPECIFICATIONS” for details.

The mains connection is made using the enclosed power cord

and a standard IEC receptacle. It meets all of the international

safety certification requirements.

+

Please make sure that all units have a proper

ground connection. For your own safety, never

remove or disable the ground conductor from the

unit or of the AC power cord. The unit shall always

be connected to the mains socket outlet with a

protective earthing connection.

8.2 Audio connections

The inputs of your V-AMPIRE come as mono 1/4" connectors.

All line out, line in and headphones outputs are configured as 1/

4" stereo connectors. The line outputs work with both balanced

and unbalanced connections.

The DI OUT outputs of your V-AMPIRE are on XLR connectors.

Fig. 8.1: XLR connectors

Fig. 8.2: 1/4" TS connector

Fig. 8.3: 1/4" TRS connector

Fig. 8.4: Headphone connector

8. INSTALLATION