TROUBLESHOOTING (cont.)

Brew cycle will not start (cont.)

Water is not hot

PROBABLE CAUSE

REMEDY

3. ON/OFF Switch

4. Start Switch

5. Timer

6. Solenoid Valve

7. Water strainer/flow control
(.222 GPM)

1. Tank Heater Switch

2. (A) Limit Thermostat
(B) Thermal Cut-Off (Brewers

with Faucet)

CAUTION - Do not eliminate or
bypass limit thermostat or
thermal cut-off. Use only BOM
replacement part.
Limit Thermostat #29329.1000
Thermal Cut-Off #20211.0100

3. Control Thermostat

4. Tank Heater

Refer to

Service

- ON/OFF

Switch for testing. See page 17

Refer to

Service

- Start Switch

for testing procedures. See page
19

Refer to

Service

- Timer for

testing procedures. See page 25
or 27

Refer to

Service

- Solenoid Valve

for testing procedures. See page
18

(A) Direction of flow arrow must
be pointing towards brewer.

(B) Remove the strainer/flow
control and check for obstruc-
tions. Clear or replace.

Refer to

Service

- Tank Heater

Switch for testing procedures.
See page 22

Refer to

Service

- Limit Thermo-

stat for testing procedures. See
page 16. Thermal Cut-Off for
testing procedures. See page 24

Refer to

Service

- Control Ther-

mostat for testing procedures.
See page 14

Refer to

Service

- Tank Heater

for testing procedures. See page
20

10478 061500