beautypg.com

Bunn CRT5 CRTF5 User Manual

Page 22

background image

Page 22

SERVICE (cont.)

TANK HEATER SWITCH

Location:

The tank heater switch is located on the rear of

the brewer on the upper left side of the trunk.

Test Procedure:
1. Disconnect the brewer from the power source.
2. Disconnect the black wire from the limit thermo-

stat.

3. With the tank heater switch in the "ON" positionand

with a voltmeter, check the voltage between the
black wire removed from the limit thermostat and
the white wire or red wire on the tank heater.
Connect the brewer to the power source. The
indication must be:
a) 120 volts ac on two wire 120 volt models.
b) 240 volts ac on three wire 120/240 volt models.
c) 200 to 240 volts ac on 200 volt or 240 volt
models.

4. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the

Wiring Diagrams

and check the brewer wiring har-

ness.

5. With the tank heater switch in the "ON" upper

position, check for continuity between the black
wire removed from the limit thermostat and the
black insert on the terminal block. Continuity
should not be present in the "OFF" lower position.

If continuity is present as described, the tank heater
switch is operating properly.
If continuity is not present as described, replace the
tank heater switch.

Removal and Replacement:
1. Shut off and disconnect the incoming water sup-

ply to the brewer.

2. On automatic brewers gently remove the fill tube

from back of fill basin.

3. Remove the tank inlet fitting securing fill basin the

tank lid. Remove fill basin and gasket. Set all three
parts aside for reassembly.

4. On brewers with faucets, disconnect the water

supply to coil assembly and remove the tube from
the tank to the faucet.

5. Remove sprayhead and hex nut securing spray-

head tube to the hood. Set aside for reassembly.

6. Disconnect the wires on the limit thermostat and

the tank heater and the control thermostat (early
models).

7. Gently pull the thermostat sensor and grommet

from the tank lid.

8. Insert a tube to the bottom of the tank and syphon

ALL of the water out. BUNN-O-MATIC has
#12440.0000 syphon assembly available for this
purpose.

9. Remove the two #8-32 screws securing the tank

assembly to the hood.

10. Lift tank and components out as an assembly and

set aside for reassembly.

11. Disconnect the two black wires from the tank

heater switch.

12. Remove the plastic facenut, hex facenut and the

switch indicator/guard bracket that secures tank
heater switch to the rear of the brewer. Remove
switch and discard.

13. Insert new tank heater switch through the hole in

the upper left rear of the trunk and secure with
switch indicator/guard bracket, hex facenut and
plastic facenut.