Diverse 4010 Classic ~ Issue 2 ~ 6th Edition ~ 1st March ’02 ~ 4413

43

To set the recall time

You need only adjust this setting if your
switchboard requires a different recall
time to the pre-set recall time of
100 MS.

Press the MENU button.

Press the DOWN button until
the display shows

BASE SET

.

Press the OK button.

Press the DOWN button until
display shows

ADD FEATURES

.

Press the OK button.

Press the DOWN button until
display shows

TBR

.

Press the OK button.

Press the DOWN button to
select the flash time

80

,

100

,

120

,

180

,

250

,

300

, or

600ms

.

Press the OK button to confirm.
The display shows

SAVED

.

Press the RED PHONE button
until you reach the idle screen.

To switch temporarily from
pulse to tone dialling

If you are using pulse dialling with your
switchboard but need tone dialling to
use certain functions on your Diverse
4010 you can switch to tone dialling
during the call.

During the call:

Press the MENU button.

Press the DOWN button until
the display shows

TEMP TONE

.

Press the OK button. Tone
dialling is now active.

MENU

OK

OK

OK

OK

MENU

OK

Please note

This setting is only for the duration of
the call.

Please note

100 MS is the standard setting for
most UK switchboards.

GENERAL

INFORMA

TION