Bosch GWH 1000 User Manual
Page 7
6 720 608 124
Installation instructions
7
3.4
Mounting Heater
Remove cover and inspect.
B
Remove the temperature control.
B
Remove the outer case by pulling it forwards and
then lifting upwards.
B
Ensure that the flue terminal is clear.
B
After inspection, replace front cover.
Install incandescent particle tray.
B
Install incandenscent particle tray using screws
provided as shown in Fig. 5.
Fig. 5
Incandescent particle tray illustration
Mounting heater.
The GWH 1000 P
is design certified for mounting on a
wall.
The heater must be mounted on a wall using
appropriate anchoring materials. If wall is a stud wall
sheathed with plasterboard, it is recommended that
support board(s), either 1x4’s or 1/2" (minimum)
plywood first be attached across a pair of studs and
then the heater should be attached to the support
boards, see Fig. 7.
B
Secure the two included L shaped hooks to wall
studs or support board 13 1/4” apart. (See Fig. 7).
B
Hang heater on two L shaped hooks. (See Fig. 8).
Fig. 6
Remove front cover
Fig. 7
Support board
Fig. 8
Secure heater to wall
Warning: before starting installation:
B
check that there are no loose parts
inside the appliance
B
ensure that gas pipe, gas valve, and
burner have no damage and are
properly fitted.
B
Read chapter 2.2 to verify proper gas
type and to check all parts are included
in box.
i
Front cover should be removed in order to
inspect
components
visually
(see
instructions below).
Warning:
B
Do not install this appliance on a
carpeted wall.
Incandescent particle tray
Screws