beautypg.com

For lp gas – Bosch GWH 1000 User Manual

Page 12

background image

6 720 608 124

12

Installation instructions

FOR NATURAL GAS
Maximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pressure drop
of 0.3 in Water Column (0.75mbar).(Based on a 0.60 Specific Gravity Gas) Btu numbers given in thousands.
Copper tubing is prohibited for use with Natural Gas in the Commonwealth of Massachusetts and not recommended
elsewhere.

Fig. 13

Follow boxed numbers for piping just one GWH 1000 P

(example: ¾” B.I. Natural Gas pipe for 20 ft (6.1m). will

handle 190,000 btu’s (55.7 kWh). For multiple appliances combine the total btu input load and then refer to
applicable chart below.

* EHD = Equivalent Hydraulic Diameter. The greater the
value of EHD, the greater the gas capacity of the tubing

.

Maximum Capacity of Semi-Rigid copper Tubing in
Thousands of BTU per Hour of Undiluted Liquefied
Petroleum Gases (at 11 inches Water Column Inlet
Pressure).

(Based on a Pressure Drop of 0.5 Inch Water Column)

* Source National Fuel Gas Code NFPA 54, ANSI Z223.1
- No Additional Allowance is necessary for an ordinary
number of fittings

FOR LP GAS

Maximum Capacity of Pipe in Thousands of BTU per Hour of Undiluted Petroleum Gases (at 11 inches Water Column Inlet
Pressure) (Based on a Pressure Drop of 0.5 Inch Water Column).

* EHD = Equivalent Hydraulic Diameter. The greater the
value of EHD, the greater the gas capacity of the tubing.

Tube
size,
inches

EHD*

10

20

30

40

50

60

1/2

18 EHD 82

58

47

41

37

34

3/4

23 EHD 161 116

96

83

75

68

1

30 EHD 330 231

188

162

144

131

1 1/4 37 EHD 639 456

374

325

292

267

Length of Flexible Corrugated Stainless Steel Tubing (CSST), Feet

Tube
size
inches

EHD*

10

20

30

40

50

60

1/2

18 EHD 129 91

74

64

58

53

3/4

23 EHD 254 183

151

131

118 107

1

30 EHD 521 365

297

256

227 207

1 1/4 37 EHD 971 661

528

449

397 359

Length of Flexible Corrugated Stainless Steel Tubing (CSST), Feet

Copper (LP gas only)

Outside

Length of Tubing, Feet

diameter
Inch

10

20

30

40

50

60

70

80

90 100

3/8

39

26

21

19

_

_

_

_

_

_

1/2

92

62

50

41

37

35

31

29

27

26

5/8

199 131 107

90

79

72

67

62

59

55

3/4

329 216 181 145 131 121 112 104 95

90

N o minal

Iro n pipe

size

inches

10

20 30 40 50 60 80 100 125 150 200

1/2

291 200 160 137 122 110 94

84

74

67

58

3/4

608 418 336 287 255 231 197 175 155 140 120

1

1145 787 632 541 480 434 372 330 292 265 227

Black Iron Pipe

Lenght of pipe, Feet

Nominal
Iron
Pipe

Internal

Size

Diameter

inches

inches

10

20

30

40

50

60

70

80

90

100 125 150 175 200

3/4

0.824

278 190 152 130 115 105

96

90

84

79

72

64

59

55

1

1.049

520 350 285 245

215 195 180 170 160 150 130 120 110 100

1 1/4

1.380

1050 730 590 500 440 400 370 350 320 305 275 250

225 210

Length of Black Iron Pipe, Feet