beautypg.com

Caution, Warning – Briggs & Stratton 5500 Watt User Manual

Page 18

background image

18

BRIGGSandSTRATTON.COM

1. To remove muffler heat shield (A) from muffler (B),

remove four screws that connect guard to muffler
bracket.

2. Remove four screws that attach spark arrester screen

(C).

3. Inspect screen and obtain a replacement if torn,

perforated or otherwise damaged. DO NOT use a
defective screen. If screen is not damaged, clean it with
commercial solvent.

4. Reattach screen and muffler guard.

Air Cooling System

Over time debris may accumulate in cylinder cooling fins and
cannot be observed without partial engine disassembly. For
this reason, we recommend you have an authorized Briggs &
Stratton service dealer clean the cooling system per
recommended intervals (see Maintenance Schedule in
beginning of Maintenance section). Equally important is to
keep top of engine free from debris. See Clean Debris.

Check Valve Clearance

Regular valve clearance check and adjustment will improve
performance and extend engine life. This procedure cannot
be done without partial engine disassembly and the use of
special tools. For this reason we recommend that you have
an authorized dealer check and adjust valve clearance at
250 hours or as recommended (see Maintenance Schedule in
the Maintenance section).

Carburetor Adjustment

The carburetor on this engine is low emission. It is equipped
with a non-adjustable idle mixture valve. Top speed has been
set at the factory. If adjustment is required, see an
authorized Briggs & Stratton service dealer.

A

B

C

A

CAUTION

Excessively high operating speeds increase risk of injury
and damage to generator.

Excessively low speeds impose a heavy load.

• DO NOT tamper with governed speed. Generator supplies

correct rated frequency and voltage when running at governed
speed.

• DO NOT modify generator in any way.

WARNING

Contact with muffler area can result in serious
burns.

Exhaust heat / gases can ignite combustibles,
structures or damage fuel tank causing a fire.

• DO NOT touch hot parts and AVOID hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 5 feet (1.5 m) of clearance on all sides of

generator including overhead.

• Code of Federal Regulation (CFR) Title 36 Parks, Forests, and

Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.