beautypg.com

Fig. 10 dispense valve wiring – Bunn CDBCF CDBCP User Manual

Page 28

background image

Page 28

SERVICE (cont.)

DISPENSE VALVE

Location:

The dispense valve is located inside the top cover

behind the front end cap.

Test Procedures:
1. Disconnect the brewer from the power source.
2. Check the water level in the tank to confirm that it

is within 1/2" from the top of the tank.

3. Connect the brewer to the power source. If the

brewer has been set for brewer temperature lock-
out, this feature must be disabled. See Page 8 for
procedure.

4. Check the dispense valve for coil action. Place the

ON/OFF switch in the "ON" position, press and
release the BREW switch. Listen carefully in the
vicinity of the dispense valve for a "clicking" sound
as the coil magnet attracts and repels the plunger.

5. Disconnect the brewer from the power source.

If the sound is heard as described, there may be a
blockage in the dispense valve or the water line to the
sprayhead. Remove the dispense valve and inspect for
wear, and remove waterborne particles.
If the sound is not heard as described, proceed to #6.

P1852

P1853

WHI/GRN from
Control Board

WHI from Terminal
Block

FIG. 10 DISPENSE VALVE WIRING

CA

UT

IO

N

:

WARMERS AND SURFACES ARE HOT

This manual is related to the following products: