beautypg.com

Bunn CDBCF CDBCP User Manual

Page 16

background image

Page 16

TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Spitting or excessive steaming
(cont.)

Brewer is making unusual noises

2a. Temperature Probe (CDBC)

2b. Temperature Probe (CEZ)

3. Control Board (all models)

1. Plumbing lines

2. Water supply

3. Lime build up

A) Remove the probe from the
grommet and submerge in a water
bath of approximately 70

°

F(21

°

C).

Connect an ohmmeter to pins 3
and 4 of the J3 connector. At
60

°

F(16

°

C) the reading should be

15.3k

±

2k OHMS, at 70

°

F(21

°

the reading should be 11.8k

±

2k

OHMS, and at 80

°

F(27

°

C) the read-

ing should be 9.3k

±

2k OHMS. If

the probe is within these param-
eters, reconnect the J3 plug to the
control board.

B) Remove the probe from the
grommet and submerge in a water
bath of approximately 70

°

F(21

°

C).

Connect an ohmmeter to pins 2
and 3 of the J5 connector. At
60

°

F(16

°

C) the reading should be

15.3k

±

2k OHMS, at 70

°

F(21

°

C)

the reading should be 11.8k

±

2k

OHMS, and at 80

°

F(27

°

C) the read-

ing should be 9.3k

±

2k OHMS. If

the probe is within these param-
eters, reconnect the J5 plug to the
control board.

Set the temperature to 200

°

F

(93

°

C). Let tank temperature sta-

bilize. If temperature in tank is
above temperature setting by more
than 7

°

F(-14

°

C), replace the con-

trol board.(See pages 21 & 22)

Plumbing lines should not rest on
the counter top.

The brewer must be connected to
a cold water supply.

Remove the tank lid and clean
inside of tank with a deliming agent,
if necessary.

HEATING CIRCUIT (cont.)

29079 042803