BREW TYPE (A/B) (Tea/Coffee)
Tea setting provides half the "purge" pressure as coffee at the end of brew
cycle.

BREW TYPE A

TEA DONE COFFEE

BREW OZ A: 8.0

(-) DONE (+)

BREW METER A: 2

- +

BREW OZ. (A/B) (1-16)
Adjust brew volume.

BREW METER (A/B) (1-5)
Simplifi ed pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.

ENTER SERVICE #
Program service phone number to be displayed anytime there is a fault mes-
sage.

ENTER PASSWORD
User must enter a 3 digit number to access remainder of adjustments. If no
number has been pre-programmed (0 0 0), then access is allowed.

ENTER SERVICE #?

NO YES

ENTER PASSWORD

0 0 0

SET PASSWORD

0 0 0

SET PASSWORD (001-999)
Program any three digit number as a password.

SET LANGUAGE
Choose between English or Spanish.

UNITS

METRIC DONE ENG

SET LANGUAGE ?

NO YES

ENTER ASSET # ?

NO YES

SET TEMP: 200°

(-) DONE (+)

SET READY: 195°

(-) DONE (+)

UNITS
Choose between English (Oz, F°) or metric (Ml, C°)

SET TEMP
Adjust tank temperature 185 to 205° F (85 to 96° C)

SET READY
Sets the minimum temperature allowable to start a brew cycle, if "BrewLockout"
is enabled. Range: (2° to 20° F) or (2° to 10° C) below the set temperature.

ENTER ASSET #
This function allows the you to enter in an optional 4 digit number. This can be
useful for tracking the usage of an individual machine within a group.

PROGRAM FUNCTIONS

SET PULSE BREW (A/B)
Individually adjust on/off times. 1st on time: OFF-.5-24.0; OFF time: OFF-.5-24.0;
Last on time: Preinfusion-.5-24.0

This will overwrite "BREW METER"

SetPulseBrew A/B ?

NO DONE YES

AIR TIME (A/B) (1-25 seconds)
Time the brew tank is purged at the end of each brew cycle.

AIR TIME A/B: 15.0

(-) DONE (+)

CONTINUED

411701 061308