beautypg.com

Bloomfield SS2 9221 User Manual

Page 16

background image

SERVICING INSTRUCTIONS (continued)

CAUTION:

SHOCK HAZARD

Disconnect brewer from electric
power before opening the
access panel.





Adjustments to be performed by
qualified technician only.

NOTE:
Brewer is pre-adjusted to deliver
1 and 1-1/2 gallons of coffee at
a water pressure of 50 p.s.i.
Use this procedure to adjust the
delivered volume to suit local
conditions.

TIMER ADJUSTMENT


PRECAUTIONS: Disconnect brewer from electric power.

Allow brewer to cool.


FREQUENCY:

As required to adjust delivered volume


TOOLS:

Phillips head screwdriver

Satellite or other container to calibrate volume


1. Press HEATER ON/OFF switch to OFF. Turn POWER

switch on back of brewer OFF.


2. Remove TOP PANEL. Operating controls are accessible

through the top panel only.


3. Adjust the TIMER setting.

NOTE: Each side has its own timer. The LEFT TIMER is for

the LEFT SIDE; the RIGHT TIMER is for the RIGHT SIDE.


Turn

CLOCKWISE to increase time;

Turn

COUNTER-CLOCKWISE to decrease time.


Adjust only in small increments to avoid large volume

variations. Recommend no more than 1/16 turn.


4. Replace TOP PANEL. Turn POWER switch ON. Press

HEATER ON/OFF switch to ON.


5. Allow the brewer to come up to brewing temperature, then

perform a test brew. Check delivered volume. Readjust as

necessary.


When desired volume is achieved, procedure is complete.

14

671 76601

O

w

ners Manual 922

1 Dual Satellite Brewer

This manual is related to the following products: