Bloomfield SS2 9221 User Manual
Page 16

SERVICING INSTRUCTIONS (continued)
CAUTION:
SHOCK HAZARD
Disconnect brewer from electric 
power before opening the 
access panel. 
 
 
 
 
 
Adjustments to be performed by 
qualified technician only. 
 
NOTE: 
Brewer is pre-adjusted to deliver 
1 and 1-1/2 gallons of coffee at 
a water pressure of 50 p.s.i. 
Use this procedure to adjust the 
delivered volume to suit local 
conditions. 
TIMER ADJUSTMENT
 
PRECAUTIONS: Disconnect brewer from electric power. 
 
Allow brewer to cool.
 
FREQUENCY: 
As required to adjust delivered volume
 
TOOLS: 
Phillips head screwdriver
Satellite or other container to calibrate volume
 
1. Press HEATER ON/OFF switch to OFF. Turn POWER 
 
switch on back of brewer OFF.
 
2. Remove TOP PANEL. Operating controls are accessible 
 
through the top panel only.
 
3. Adjust the TIMER setting. 
 
NOTE: Each side has its own timer. The LEFT TIMER is for
the LEFT SIDE; the RIGHT TIMER is for the RIGHT SIDE.
 
 Turn 
CLOCKWISE to increase time;
Turn
COUNTER-CLOCKWISE to decrease time.
 
 
Adjust only in small increments to avoid large volume
variations. Recommend no more than 1/16 turn.
 
4. Replace TOP PANEL. Turn POWER switch ON. Press 
 
HEATER ON/OFF switch to ON.
 
5. Allow the brewer to come up to brewing temperature, then 
 
perform a test brew. Check delivered volume. Readjust as
 necessary. 
 
 
When desired volume is achieved, procedure is complete. 
14
671 76601
O
w
ners Manual 922
1 Dual Satellite Brewer