beautypg.com

Buhler Commercial Snowblower User Manual

Page 33

background image

Commercial Snowblower

32

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

REMEDY

D1 Nothing Works

Hydraulic Circuit Not Complete

1. Hydraulic Valve not engaged

1. Engage valve to full detent

2. 1 or more quick couplers not

2. Fully engage all couplers

completely engaged.

3. Defective quick coupler

3. Replace defective quick couplers

4. Hydraulic pump low on fluid

4. Top up fluid level

D2 Auger Rotates

Hydraulic Circuit Reversed

backwards, and

1. Main valve is in reverse

1. Reverse valve direction or

fan does not

2. Quick couplers are connected

2. Switch hose connections to

rotate

backwards.

the machine.

D3 Fan turns too

1. Inadequate hydraulic flow for

1. Check the gpm of your

slow

this motor size.

system.

2. Wrong motor for your system.

2. Contact your dealer.

D4 Fan motor stalls

Valve #4 (Fig. 1) set too high

See MODULATING

ELEMENT SET UP

D5 Auger motor

Valve #4 (Fig. 1) set too low

See MODULATING

slows or stalls

ELEMENT SET UP

too quickly

D6 Fan & Auger work

Electrical Problem

but chute controls 1. Electrical connections to battery

1. Ensure that the clamps are

do not work

making proper connection.

properly

2. Breaker is tripped.

2. Reset breaker.

3. Connector from Sw to block not

3. Ensure the connector is

contacting.

fully engaged. Check for

broken wires.

4. Connection to No-Load Valve #6

4. Check all items in D6

(Fig. #1) is not making

5. Diodes in switchbox are defective.

5. Check for voltage through diodes

6. Solenoid Valve Spool is stuck

6. Replace #8a or 8b solenoid

cartridge.

D7 Chute controls do 1. The No-Load pressurizing valve

1. Back of the adjuster-screw

not work properly

#14a (Fig. #1) set too low.

till it rotates freely by hand. Then

in no-load

turn in till you feel it contacting the

conditions.

spring. Then turn in 2 turns.

2. Electrical: Switch, harness,

2. Check the No-Load Circuit

connectors, coil 10a, diodes

#5 in Fig. #2

3. Polarity of the system is reversed.

3. Red Alligator clip must be

on the Positive Terminal

4. Diodes in switchbox defective.

4. Replace defective diodes.

5. Defective Coil #10a (Fig. #1)

5. Replace Coil.

6. Defective Valve #6 (Fig. #1)

6. Replace Valve.

D8 Chute Rotation

1. See D7-1

1. Same as D7-1.

seems to lack

2. Valve #14b or #14c set too low.

2. Back of the adjuster-screw

power to turn.

till it rotates freely by hand

then turn in till you feel it

contacting the spring. Then

turn in 2 turns.