Whirlpool GXW7230DAS User Manual
Whirlpool Kitchen
PRODUCT MODEL NUMBERS
GXW7230DA
ELECTRICAL REQUIREMENTS
• A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical circuit is required.
VENTING REQUIREMENTS
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, by fitting a charcoal filter
and the deflector. Fumes and vapors are recycled through the top grille. See the
“Assistance or Service” section for information on ordering.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters)
for each vent piece used in the system.
30" (76.2 CM) Wall-Mount Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10458667A
9/13/12
Roof Venting
Wall Venting
Non-vented
(recirculating)
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Deflector
B. 6" (15.2 cm)
round vent
A
A
B
B
B
A
Example vent system
The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
LOCATION REQUIREMENTS
Have a qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located behind
the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as
windows, doors and strong heating vents.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24,
HUD, Part 280) or when such standard is not applicable, the standard
for Manufactured Home Installation 1982 (Manufactured Home Sites,
Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or
with local codes.
PRODUCT DIMENSIONS
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
*For non-vented (recirculating) installations
**For vented installations
30" (76.2 cm)
10"
(25.4 cm)
20" (50.8 cm)
14
¹⁄₈"
(35.9 cm)
7
¹⁄₄"
(18.4 cm)
8
¹⁄₈"
(20.7 cm)
*28
⁷⁄₈" (73.3 cm) min.
42
¹⁄₁₆" (106.9 cm) max.
**28
³⁄₈" (72.0 cm) min.
38" (96.6 cm) max.
1 " (4.0 cm)
Page 1 of 2