beautypg.com

Whirlpool W3CG3014XS User Manual

Gas built-in cooktop

background image

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

CABINET OPENING DIMENSIONS

GLT3057R

GLT3657R

W3CG3014X

Natural Gas:

This cooktop is design-certified by CSA
International for use with Natural gas or, after
proper conversion, for use with LP gas.

This cooktop is factory set for use with Natural gas.
If converting to LP gas, see the following “LP Gas
Conversion” section. The model/serial rating plate
located on the underside of the cooktop base has
information on the types of gas that can be used. If
the types of gas listed do not include the type of gas
available, check with the local gas supplier.

LP Gas Conversion:

Conversion must be done by a qualified service
technician.

No attempt shall be made to convert the cooktop
from the gas specified on the model/serial rating
plate for use with a different gas without
consulting the serving gas supplier. See the Gas
Conversion instructions provided in the package
containing literature.

Electrical:

A 120-volt, 60-Hz, AC-only, 15-amp

fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only
this cooktop be provided.

Gas Built-in Cooktop

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10526074A

9/13/12

Straight-edge glass cooktops

A

B

C

C

A

B

Curved-edge glass cooktops

A

B

C

Metal Cooktops

A. 31

⁷⁄₁₆" (79.8 cm) on 30" (76.2 cm) models,

37

⁹⁄₁₆" (95.4 cm) on 36" (91.4 cm) models

B. 21

¹⁄₄" (53.4 cm)

C. 2

⁷⁄₈" (7.3 cm)

A. 20

⁵⁄₁₆" (51.5 cm)

B. 30

³⁄₁₆" (76.8 cm) on 30" (76.2 cm) models,

36

⁷⁄₁₆" (92.5 cm) on 36" (91.4 cm) models

C. 2

⁷⁄₈" (7.3 cm)

A. 21

¹⁄₈" (53.7 cm)

B. 30

⁵⁄₁₆" (77.0 cm) on 30" (76.2 cm) models,

36

⁵⁄₁₆" (92.3 cm) on 36" (91.4 cm) models

C. 2

⁷⁄₈" (7.3 cm)

B

D

A

C

E

F

H

I

J

G

K

L

M

J

A. 30

"

(76.2 cm) on 30

"

models; 36

"

(91.4 cm) on 36

"

models

B. Combustible area above countertop (shown by dashed box)

C. 30

"

(76.2 cm) minimum clearance between top of cooktop

platform and bottom of unprotected wood or metal cabinet
(24

"

[61 cm] minimum clearance if bottom of wood or metal

cabinet is protected by not less than

"

[0.6 cm] flame

retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015

"

[0.04 cm] stainless steel, or

0.024

"

[0.06 cm] aluminum or 0.020

"

[0.05 cm] copper)

D. 13

"

(33 cm) recommended upper cabinet depth

E. 2

¹⁄₈

"

(5.4 cm)

F. 19

"

(48.3 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to

countertop within minimum horizontal clearances to cooktop

H. Grounded outlet - Locate within 24" (61 cm) of right rear

corner of cutout

I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models

J. 8

³⁄₈" (21.3 cm) minimum distance to nearest left and right side

combustible surface

K. 2

⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface

L. Gas line opening - Wall: anywhere 5" (12.7 cm) below

underside of countertop. Cabinet floor: Anywhere within
6" (15.2 cm) of rear wall is recommended

M. 24" (61 cm) minimum countertop depth is required

¹⁄₄

IMPORTANT:

If installing a range hood or microwave hood

combination above the cooktop, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.

NOTES:

After you make the countertop cutout, some

installations may require notching down the base cabinet side
walls to clear the cooktop base. To avoid this modification, use a
base cabinet with sidewalls wider than the cutout.

If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened to
avoid interfering with the regulator.

TYPE OF GAS

This manual is related to the following products: