Because Whirlpool Corporation policy includes a continuous commitment to improve

Dimensions are for planning purposes only. For complete details, see Installation

our products, we reserve the right to change materials and specifications without notice.

Instructions packed with product. Specifications subject to change without notice.

ELECTRICAL REQUIREMENTS

VENTING REQUIREMENTS

E

xhaust venting: Exhaust your dryer to the outside. 4" (102 mm)

diameter vent is required. Rigid or flexible metal exhaust vent

must be used. Do not use plastic or metal foil vet. Exhaust hood

must be at least 12" (305 mm) from the ground or any object that

may be in the path of the exhaust.

Louvered Hood

Angled Hood

Box Hood

Exhaust hoods:

Recommended Styles:

Acceptable Style:

The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.

Damage to the coupling can result.

A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit

are recommended.

GAS SUPPLY REQUIREMENTS

Gas supply

:

This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When

acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger

tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed

within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.

WATER (STEAM MODELS ONLY) REQUIREMENTS

Determine vent path:

Select route that will provide straightest and most direct

path outdoors.

Plan installation to use fewest number of elbows and

turns.

When using elbows or making turns, allow as much

room

as possible.

Bend vent gradually to avoid kinking.

Use as few 90° turns as possible.

INSTALLATION REQUIREMENTS

Standard Vent System Chart

Number of

90° elbows

Type

of vent

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

Determine vent length and elbows needed for best

drying performance:

Use the “Vent System Charts” on the next page to determine

type of vent material and hood combinations acceptable to

use.

NOTE: Do not use vent runs longer than those specified

in “Vent System Charts.”

Exhaust systems longer than those specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times

and increased energy usage.

Long Vent System Chart*

Number of

90° elbows

Type

of vent

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

160 ft. (48.8 m)

150 ft. (45.7 m)

140 ft. (42.7 m)

130 ft. (39.6 m)

120 ft. (36.6 m)

* For Model WGD71HEW only; for all other models, refer to the

Standard Vent System Chart above. To find your model number,

refer to the model and serial number plate in the inner door well.

NOTE: For long vent systems, use of box/louvered hoods will

improve venting regardless of length.

This manual is related to the following products: