Service (cont.), Rectifier - g1md only – Bunn G2 User Manual
Page 17
17
+
A
C
A
C
SERVICE (cont.)
Removal and Replacement:
1.
Disconnect the wires from the rectifier.
2.
Remove the #10-32 screw securing the rectifier
to the motor mounting bracket.
3.
Remove the rectifier and discard.
4.
Install new rectifier on the rear of the motor
mounting bracket and secure with a #10-32
screw.
5.
Refer to Fig. 13 and reconnect the wires.
BLK from Motor (+)
BLU to BLU from Motor (AC)
WHI from Main Harness (AC)
RED from Motor (-)
FIG. 13 RECTIFIER TERMINALS
P1381
RECTIFIER - G1MD ONLY
CLE
ANIN
G LEVER
CLEANING LEVER
GR
OUND
COFFEE