Technical data – Glen Dimplex Home Appliances Ltd BI 90 G User Manual
Page 33

Technical Data
Data badge
Lower part of front frame and the rear
panel of the appliance
Pressure setting
Natural Gas G20 @ 20 mbar (8”wg)
Gas category
Natural gas - I
2H
Appliance class
Class 3 double oven and grill
Ignition
Mains operated re-ignition generator
Electrical supply
220 - 240V ~ 50Hz
Main Oven
Bray type burner, sheet steel body,
stainless steel flame strip
Nominal Rate Qn
2.5kW
Injector
115
Spark gap
3 - 4mm
Thermostat
50
Oven injector - If the injector is
removed or replaced for and reason, it
is mandatory to apply Hylomar PL32
or Plasticol X10 sparingly to the thread
prior to (re)fitting.
Top oven
Nominal rate Qn
1.8kW
Injector
Amal 130
Spark gap
3 - 4mm
Thermostat bypass
50
Oven injector - If the injector is
removed or replaced for any reason, it
is mandatory to apply Hylomar PL32
or Plasticol X10 sparingly to the thread
prior to (re)fitting.
Maximum heat input
∑
∑ Qn 4.75kW
Countries of destination
GB - Great Britain
IE - Ireland
31