B&B Electronics EIR618-2SFP-T User Manual
Page 59

Manual Documentation Number: EIR618-2SFP-T_5107m
47
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
event smtp
[Link-UP|Link-Down|Bot
h]
I
Set port event for
SMTP
switch(config)#interface
fastethernet 3
switch(config-if)#event smtp both
show event
P
Show event selection switch#show event
no event
device-cold-start
G
Disable cold start
event type
switch(config)#no event
device-cold-start
no event
authentication-failure
G
Disable Authentication
failure event typ
switch(config)#no event
authentication-failure
no event
X-ring-topology-change
G
Disable X-ring
topology changed
event type
switch(config)#no event
X-ring-topology-change
no event systemlog
I
Disable port event for
system log
switch(config)#interface
fastethernet 3
switch(config-if)#no event
systemlog
no event smpt
I
Disable port event for
SMTP
switch(config)#interface
fastethernet 3
switch(config-if)#no event smtp
show systemlog
P
Show system log client
& server information
switch#show systemlog
SNTP Commands Set
Commands
Level Description
Example
sntp enable
G
Enable SNTP function switch(config)#sntp enable
sntp daylight
G
Enable daylight saving
time, if SNTP function
is inactive, this
command can’t be
applied.
switch(config)#sntp daylight
sntp daylight-period
[Start time] [End time]
G
Set period of daylight
saving time, if SNTP
function is inactive,
this command can’t be
switch(config)# sntp
daylight-period 20060101-01:01
20060202-01:01