ROOM THERMOSTAT

A room thermostat may be fitted for control of the central heating

temperature. It will be located in one room of the home. The method

of setting a room thermostat varies with the type and manufacture.

Refer to the instructions supplied with the room thermostat.

PROGRAMMER/CLOCK

A programmer or clock may have been fitted to the system: the

method of setting varies with the type and manufacturer.

Refer to the instructions supplied with the control.

THERMOSTATIC R

ADIATOR V

AL

VES

If thermostatic radiator valves are fitted to the system then they

must conform to the requirements of BS2767. The radiator located in

the room where the room thermostat is sited must be controlled by a

thermostatic radiator valve.

VENTILA

TION OF ROOM SEALED FANNED

FLUE (RSF) APPLIANCES

These appliances do not require air flow for combustion from the

room in which they are installed. Any cooling ventilation openings in

a wall or door must not be obstructed. Do not allow the flue terminal

fitted on the outside wall to become obstructed or damaged.

NOTE: Do not place anything on top of the appliance. If the

appliance is fitted in a compartment do not use the compartment for

storage purposes unless it conforms to the requirements of

BS 6798:1987: Section 6. It is essential that the airing space is

separated from the boiler space by a perforated non-combustible

partition as described in BS 6798:1987.

If the clearances are less than shown for an unvented compartment

then the compartment must be ventilated in accordance with BS5440.

FLUE TERMINAL

Do not allow the flue terminal fitted on the outside wall to

become obstructed or damaged.

CIRCULA

TING PUMP

The heating system will be filled with a circulating pump which

may be fitted with a speed adjuster. If so it will be set by the installer

to suit the heating load. Do not alter the setting.

10

INDICATOR LIGHTS

Boiler demand :

System is calling for heat

Burner ON

:

Burner is firing

Lock-out

:

There is a fault condition

Steady light - Overheat

Flashing light - Flame failure

TO LIGHT THE APPLIANCE

Check that the water valves to the central heating circuit are open.
Check that the needle on the pressure gauge is not below the

required pressure - sealed system only.

Switch on the mains electricity. Set the room thermostat, if

fitted, to maximum. Turn the boiler temperature control fully
clockwise to the maximum position. The burner will light. Set the
boiler temperature control and the room thermostat/cylinder
thermostat, if fitted, to the desired temperature.

TO STOP THE APPLIANCE

For Short Periods

Turn the boiler temperature control fully anti-clockwise to the

‘O’ position.
For Long Periods

Turn the boiler temperature control switch to the ‘O’ position.

Switch off the mains electricity.

Any programmer will require resetting if mains supply has been

disconnected.

ELECTRICITY SUPPLY
FAILURE

If the electricity supply fails the appliance will not operate.

Once the supply is restored the appliance will return to normal
operation.

Check that the settings of any programmer or time control

have been maintained.

7

FROST PRECAUTIONS

If the appliance is not to be used for a long period of time and

there is a likelihood of freezing, then the appliance should be drained.
The Worcester Technical Helpline will advise you on suitable frost
precautions. The boiler has an in-built frost thermostat which will
protect the appliance should the temperature of the boiler drop below
approximately 10°C.

SERVICE

Annual servicing is important in order to ensure continuing

high efficiency and long life for your appliance. In the event of any
difficulty in making suitable servicing arrangements, Worcester
personnel or other competent persons will discuss regular servicing
arrangements and offer a comprehensive maintenance contract.

WARNING

If a gas leak exists, or is suspected, turn off the gas supply to the

appliance at the service cock on the meter and consult your local
service engineer.

Do not touch any electrical switches to turn them either on or off.

Open all windows and doors. Do not smoke. Extinguish all naked lights.

CLEANING

Do not use abrasive cleaners on the outer casing. Use a damp

cloth and a little detergent.

APPLIANCE LOCKOUT

The appliance can be reset by turning the boiler temperature

control fully anti-clockwise and back. Check that the gas supply has

not been interrupted.

If this condition continues to occur, then call a service engineer.