Real Time Clock

Problem

Procedure

The BIOS setting
and system date/
time are lost.

The charge in the Real Time Clock (RTC) battery
has run out - you will need to set the date and time
in the BIOS setup application by using the
following steps:
1.

Press and hold the F2 key, and then turn on
the computer. Release the F2 key one second
after the computer is power on.

2.

Set the date in the System Date field.

3.

Set the time in the System Time field.

4.

Press F10 - a confirmation message will be
displayed.

5.

Press the ENTER key - the BIOS setup
application will end and the computer will
restart.

Keyboard

Keyboard problems can be caused by the setup and configuration of the
computer - please refer to the

The Keyboard

section for further information.

Problem

Procedure

Output to screen is
garbled

Please refer to your software's documentation to
ensure that it is not remapping the keyboard in any
way (remapping involves changing or reassigning
the function of each key).
If you are still unable to use the keyboard, you
should contact TOSHIBA Support.

Internal display panel

Apparent computer's display panel problems may be related to the
computer's setup and configuration - please refer to the

TOSHIBA System

Settings

section, for further information.

Problem

Procedure

No display

Press the function keys to adjust the display
priority, and to make sure it is not set for output to
an external monitor.

User's Manual