STEP 3: MINIMUM FLAME ADJUSTMENT

WARNING!

These adjustments should be made only for use

of the appliance with natural gas. For use with

liquid propane gas, the choke screw must be

fully turned in a clockwise direction.

SURFACE BURNERS

1. Light one burner at a time and set the knob

to the MINIMUM position (small flame).

2. Remove

the

knob.

3. The range is equipped with a safety valve.

Using a small‐size slotted screwdriver, locate
the choke valve on the valve body and turn
the choke screw to the right or left until the
burner flame is adjusted to desired minimum.

4. Make sure that the flame does not go out

when switching quickly from the MAXIMUM
to the MINIMUM position.