beautypg.com

Bertazzoni (A User Manual

Page 16

background image

16

5) Remove damaged supply cord set by taking

off the 4 electrical connection screws (block
L1, N, L2 and Ground screw, see diagram)

6) Insert the new supply cord set in the strain

relief and lock it with two strain relief's
screws in suitable position.

7) Fix well the ring terminals G, L1, N, L2 of the

new supply cord set as shown in diagram
with its 4 screws

8) Re‐install the back enclosure panel with 6

screws

9) Slide the appliance back into its proper

location

10) Re‐connect the appliance to the electrical

power.

ELECTRICAL GROUNDING

This appliance is equipped with a four‐prong plug
for your protection against shock hazard and
should be plugged directly into a properly
grounded receptacle. Do not cut or remove the
grounding prong from this plug.

WARNING!

ELECTRICAL SHOCK HAZARD

Disconnect electrical power at the circuit

breaker box or fuse box before installing the

appliance.

Provide appropriate ground for the appliance.

Use copper conductors only.

Failure to follow these instructions could result

in serious injury or death

CAUTION

Label all wires prior to disconnecting when

servicing controls. Wiring errors can cause

improper and dangerous operation.

Verify proper operation after servicing

LOCATION OF APPLIANCE PLATES

The data rating plate shows the model and serial
number of your range. It is located under the
front edge of the range cooktop, and is visible
when the oven door is open (see illustration)

A= Rating plate(s) located under front edge of
cooktop

B= Wiring / schematic diagram placed on