ToughRunners / ScanWear – Communication Protocol v1.2
- 21 -
Data Capture
for Workforce
in Motion
Command ID
0xA4
Description
Get data suffix
Length
0
payload
None
Response
0-32 bytes: suffix
Default settings :
No suffix
Command ID
0xA5
Description
Set data suffix
Length
0-32
payload
suffix
Response
0 (1 = ERROR)
Command ID
0xA6
Description
Get data prefix
Length
0
payload
None
Response
0-32 bytes: prefix
Default settings :
No prefix
Command ID
0xA7
Description
Set data prefix
Length
0-32
payload
prefix
Response
0 (1 = ERROR)