25

Fig. 8

Fig. 9

By pass screw

WARNING: Servicing shall only be

carried out by authorised personnel.

Substitution of the nozzles

- Remove the grills;

- Remove the caps and baffles from the

burners;

- With a tubular spanner no. 7 unscrew

and remove (fig. 8) the nozzles

substituting them with those

corresponding to the type of gas used

(see table on page 18);

- Remount the parts carrying out the

operations described in reverse. Upon

completion remove existing gas type

label and stick the relevant gas type label

near the gas supply pipe.

If the pressure of gas used is different (or

variable) from that foreseen an appropriate

pressure regulator should be installed on

the entry tube. In case pressure regulators

for U-LPG are used these should conform

to the regulations in force.

Regulation of the minimum

To regulate the minimum:

- bring the tap to the minimum flame

position.

- extract the knob.

- in case of conversion from natural gas

to U-LPG, tightly screw the by-pass

screw (Fig.9);

- when converting from U-LPG to natural

gas unscrew about ½ turn by-pass

screw, until a regular small flame is

reached.

Finally check that by quickly turning the

tap from the maximum position to the

minimum position the burner is not

extinguished; remount the parts carrying

out the operations described in reverse.

Adaptation to different types of gas

FO 0392

Tap

Burner

Ø By-pass

of tap

1/100 mm

Auxiliary

28

Semi-rapid

35

Rapid

45

Double crown

56