Connection

Carry out the connection to the gas plant

only by means of a rigid metallic pipe

conforming to the regulations in force.
The joint for the entry of gas into the

appliance is threaded GJ 1/2".
Carry out the connection avoiding any type

of stress on the appliance.
Natual gas appliances must be fitted with a

pressure regulator and be installed at the

inlet connection. The gas pressure must

then be set as a part of the commissioning

procedures.
For U-LPG the pressure adjustment is

made via the regulator fitted at the domestic

cylinder.

Important

Upon completion of installation, always

check:

l

that all the joints are completely sealed

by using a soapy solution, never a flame;

l

that the gas pressure has been

regulated to 1.00kPa for Natural Gas

and 2.75kPa for Universal-LPG. The

pressure test point is located on the

regulator for Natural Gas models or at

the top left hand rear of the cooker for

U-LPG models. The pressure should be

measured and adjusted with the Wok

burner on high flame;

l

that the automatic ignition system is

operating satisfactory on all burners,

both individually and in combination;

l

that the burners operate correctly, are

stable, without yellow tipping or

excessive noise on high and low flame.

Then demonstrate to the customer the

appiance operation and leave these