Classic Circular 36"/54" Washfountain with Foot Control
WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Installation Instructions
Bradley Corporation • 215-603 Rev. M; EN 06-915B
4
4/6/2007
Length of Tie Pipe Required for Vent Through Washfountain Column
54" Less Soap Dispenser
21-1/2" (546mm)
36" Less Soap Dispenser
18" (457mm)
54" With Soap Dispenser
30" (762mm)
36" With Soap Dispenser
26-1/2" (673mm)
54" Less Soap Dispenser With Towel Dispenser
55-1/2" (1410mm)
36" Less Soap Dispenser With Towel Dispenser
52" (1321mm)
54" With Soap Dispenser With Towel Dispenser
48" (1219mm)
36" With Soap Dispenser With Towel Dispenser
44-1/2" (1130mm)
54" With Cube Adapter
32" (813mm)
36" With Cube Adapter
28-1/2" (724mm)
54" With Cube Adapter With Towel Dispenser
50" (1270mm)
36" With Cube Adapter With Towel Dispenser
46-1/2" (1181mm)
54" With Cube Adapter And Soap Dispenser
40" (1016mm)
36" With Cube Adapter And Soap Dispenser
36-1/2" (927mm)
Type
Pipe Length
NOTE: Drain must be connected with 2" schedule 40 welded wrought iron pipe, minimum, to provide
lower support for this installation. Vent or support pipe must be of the same material in 1-1/2".