Shop charging device wm18 - 24 v – AEG Workshop charger WM 18 User Manual
Page 27

GB
27
24 V
Once the battery has reached a voltage between 28.2 V and 28.7 V the battery is
fully charged. As soon as the voltage drops to 26.7 V maintenance charging will
start.
End charging process
1. Unplug from the AC outlet.
2. Disconnect the charging clamp (black) from the vehicle’s body, in exceptions
from the negative battery terminal (marked N or -).
3. Disconnect the positive charging clamp (red) from the positive battery terminal
(marked P or +).
Voltage “V”
maintenance charge
27.2
28.7
26.5
24
21
5.4 - 6A
4.3 - 5.2A
Shop charging device WM18
- 24 V
3.2 - 4.1A
1.8 - 2.6A
<1A
26.7(v)
27.5 - 28.7(v)
26.7 - 27.4(v)
25.5- 26.4(v)
21- 24.5(v)
Time "t"
Charging current “A”