FITTING THE HOOD BODY
• Open the top suction panel and fasten it to the
hood body on the left using the pin, so that it
does not close again.
• Unlock the lower suction panel by removing the
fixing pin on the left, and open it.
• Remove the Metal grease filters using the handles
provided.
• Adjust the two screws
Vr, in the brackets 11a, so
that they are at the start of their travel.
• Hook the hood body to the two brackets
11a.
• From the inside of the hood body, turn screws
Vr
to level the hood body itself.
• Fasten the safety screws
11.
• Close the suction panels.
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood
to the chimney using either a flexible or rigid pipe
ø 150 or 120mm, the choice of which is left to the
installer.
To install a ø 150 pipe
• To install the dumper
10
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection,
insert the reducer flange
9 on the dumper 10.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
.
• Screw the filter cover onto the air outlet, using
four screws
12c (2.9 x 12.5).
• Fix the directional grille
8 on the recirculation air
outlet using the 2 screws
12d (2,9 x 9,5) pro-
vided.
ш 120
ш 150
10
10
9
Vr
11
11a
16
12c
12d