PROBLEM

6. Dispensing pump runs but will not pump water.

7. Dispensing nozzle leak.

CAUSE

6. A. Water tank valve shut off.

B. Failed pump.
C. Failed dispensing/recirculation solenoids.

7. Dirt in solenoid.

CORRECTION

6. A. Open valve.

B. Replace pump.
C. Replace solenoid.

7. Clean solenoid.