Multitasker – Altinex MT110-103 User Manual
Page 12
![background image](/manuals/47457/12/background.png)
MULTITASKER
400-0197-006
11
All status feedback is enclosed in brackets, “[ ]“.
Each data field within the status is enclosed in
parentheses. The first two characters identify
the status type. The last three characters are the
card’s ID.
MT110-103
= Card model number
VR690-0152-011
= Firmware version
ON1111111
= Output ON/OFF status
MA01010101...01
= Matrix connections
MX8x8C04
= Matrix configuration
VO323232...32
= Output volume settings
MU0C04
= Mute status
The ON/OFF status line is read from left to right
as Outputs 1-8. A "1" indicates the output is on
and a "0" indicates the output is off.
The matrix connections are also read left to right
representing Outputs 1-8 and the input to which
each is connected. The first two digits show the
input number to which Output 1 is connected.
The third and forth digits are for Output 2 and so
on.
The matrix configuration is the size of the matrix.
In this case, the matrix has 8 inputs and 8
outputs.
The output volume settings are read left to right
representing Outputs 1-8 and the volume to
which each is set. The first two digits show the
volume level for Output 1. The third and forth
digits are for Output 2 and so on.
11. [STA1]
This command enables automatic feedback
from the front panel. The command affects any
card with auto-feedback capability, not just the
MT110-103. The default at power on or reset is
STA0, off. For more details, see the [?Cn]
command definition.
Command Format: [STA1]
Feedback Prefix Definitions:
MT Card model number
VR Firmware version
ON Output on/off status
MA Matrix connections
MX Matrix configuration
VO Output volume
MUMute
Example:
Command = [I1O*C4]
Feedback = (MA0101010101010101C04)
MA
= Matrix connections
0101...01 = Input 1 to all outputs
C04
= Card ID/slot number
12. [STA0]
This command disables automatic feedback
from the card and front panel. The command
affects any card with auto-feedback capability,
not just the MT110-103 card.
The default at
power on or reset is STA0, OFF.
Command Format: [STA0]
13. […F] – FEEDBACK
After processing a command, an “OK” or
“[ERR001]” will be returned as feedback if “F” is
included at the end of a command string.