Super adg-30ds (gas) n, Super ads-30ds (steam) n, Super adg-30ds (gas) r – American Dryer Corp. Super AD-30 User Manual
Page 27: Super ads-30ds (steam) r

23
NOTE: Contact Factory for electrical information not listed.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
SUPER ADG-30DS (Gas) N
ON
-R
EVERSING
SUPER ADS-30DS (Steam) N
ON
-R
EVERSING
E
LECTRIC
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX. AMP
DRAW
FUSING
CIRCUIT
BREAKER
60 HZ
50 HZ
Dual Element
Time Delay
120
1ш
2
13
---
17.5
25
208
1ш
2
7.6
---
12
15
230/240
1ш
2
7
4.9
12
15
208
3ш
3
4.8
---
6.25
15
230/240
3ш
3
5
5.5
6.25
15
380
3ш
3/4
---
3
5
15
416
3ш
3/4
---
3.1
5
15
460/480
3ш
3/4
2.8
---
4.5
15
575
3ш
3
2.5
---
4.5
15
SUPER ADG-30DS (Gas) R
EVERSING
SUPER ADS-30DS (Steam) R
EVERSING
E
LECTRIC
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker
size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX. AMP
DRAW
FUSING
CIRCUIT
BREAKER
60 HZ
50 HZ
Dual Element
Time Delay
208
3ш
3
4.8
---
6.25
15
230/240
3ш
3
5
5.5
6.25
15
380
3ш
3/4
---
3
5
15
416
3ш
3/4
---
3.1
5
15
460/480
3ш
3/4
2.8
---
4.5
15
575
3ш
3
2.5
---
4.5
15