ADCP-75-192 • Issue 2 • June 2007

Page 15

© 2007, ADC Telecommunications, Inc.

*’U’ numbers are printed on the rack rails of the OP-HUB2 rack.

Hub Racks are numbered sequentially: Rack1, Rack2, and so on, or by serial number. The
following guidelines apply:

• Chassis in Hub racks are numbered by ‘U’ number. For example, the lowest RF chassis

shown in

Table 4

would be numbered U12.

• BIMs in racks are numbered by ‘U’ number. For example, the lowest BIM shown in

Table 4

Would be numbered U8.

• Power Attenuators are located at the top of the Hub rack or mounted to a wall.

• WSP Base stations should be given unique Tenant Name and BTS ID designations.

• Each base station sector is cabled to a separate attenuator and BIM unit in the Hub rack.

2.2

MIB Relationships

As explained in

Section 1.4.2 on Page 4

, the Digivance CXD/NXD system uses Management

Information Bases (MIBs) accessed with an SNMP manager (or EMS) to provide a user
interface for querying and configuring perrformace objects and being notified of alarms. This
section describes the relationships between MIBs that are relevant when cofiguring and
operating the system.

Ethernet Hub 1U

U38

Digital Chassis (top) 4U

U37

BIM 1U

U33

RF Chassis (top) 4U

U32

BIM 1U

U28

Digital Chassis (top) 4U

U27

BIM 1U

U23

RF Chassis (top) 4U

U22

BIM 1U

U18

Digital Chassis (top) 4U

U17

BIM 1U

U13

RF Chassis (top) 4U

U12

BIM 1U

U8

Reference Module (bottom) 1U

U7

Table 4. Hub Rack Numbering

CHASSIS OR SHELF HEIGHT

LOCATION*