Optical transmit power output
Standard range
Extended range

0 dBm
0 dBm

Typical

Optical receive input
Standard range
Extended range

–9 dBm
–26 dBm

Optical budget
Standard range
Extended range

9 dB
26 dB

Typical

Optical connectors

LC

Dual-connector

Battery backup options
Internal – RFA Slot Assembly
External

1 hour
2 hour

Takes one RFA slot
Requires Extended Cabinet

Battery Weight
Internal – RFA Slot Assembly
External

61 lbs.
140 lbs.

Two batteries and tray
Two batteries

Table 3. NXD RAN Specifications

ITEM

SPECIFICATION

COMMENT

Physical and Mechanical

Dimensions (HxWxD)

36.5 x 31.0 x 24.0 inches
(92.7 x 78.7 x 60.1 cm)

Weight
with extended batteries (4)

300 lbs. (136.4 kg)
625 lbs. (284.1 kg)

RAN without batteries
Total RAN + 4 batteries

Color

Putty white

Bands per box

Up to 4

Boxes per RAN site

Up to 2 RANs

RF connections

RAN cabinet has
5 Type N plugs

Cable type: CommScope PN
540ANM or equivalent

Environmental and Thermal

Box thermal management

External air

Variable speed fans (PIC/PA
Assembly and cPCI)

Operating temperature

-40 to +50 degrees C

-40 to 122 degrees F

Cold-start temperature

-20 to +50 degrees C

-4 to 122 degrees F

Storage temperature

-40 to +85 degrees C

-40 to 185 degrees F

Internal air temperature

0 to 60 degrees C

32 to 140 degrees F

Weather resistance

NEMA-3R

Operational humidity

95%

Acoustic emissions

63 dBA

Table 2. CXD RAN specifications, continued

ITEM

SPECIFICATION

COMMENT