14

1)

Options / model variants

Original instruction

NEPTUNE 1, NEPTUNE 2
NEPTUNE 2 Special

8 Troubleshooting

8.1

Indications on Display

Indication lights

Cause

Remedy

>

>

The light is constant
- The appliance is ready for

operation

Flashing light
- Flow sensor fault
- Water tap closed or water

shortage

- Detergent tank empty
- Pressure regulation on the

safety control blocks or
the VarioPress

1)

lance is

set to low water volume

- Machine scaled
- Spray gun is leaking
- High pressure hose,

coupling or line system is
leaking

- Motor is overheated

3)

> Refuel detergent or set SDR

value to “0“

Turn main switch to position
“OFF“ - let the machine cool
down
Remove/disconnect exten-
sion cable

>

Constant light
- Low fuel level

>
>

Top up fuel
Cold water operation is pos-
sible

>

Flashing light
- Low Nilfi sk-ALTO Anti-
Stone level

1)

> Top up Nilfi sk-ALTO Anti-

Stone

>

>

Constant light
- Service interval has

expired

Flashing light
- Service interval due in 20

hours

- Microprocessor error

>

>

>

Contact Nilfi sk-ALTO Service

Contact Nilfi sk-ALTO Service

Machine shutdown

>

Constant light
- Boiler overheated.

Exhaust sensor (EXT-H)
has cut off fuel supply

- Insuffi cient water fl ow
- Machine scaled
- Boiler not serviced

>

>
>

Machine shuts down. Cold
water operation is possible.

Check water supply
Contact Nilfi sk-ALTO Service

>

Constant light
- Flame sensor (B7) is

sooted

- Ignition or fuel system

failure

>

>
>

Clean fl ame sensor (B7) (see
chapter 7.2.4)
Contact Nilfi sk-ALTO Service
Cold water operation is pos-
sible

3)

For NEPTUNE 1 only. For NEPTUNE 2 overheating warning see next page.