beautypg.com

G. h – APW Wyott FDDLB User Manual

Page 9

background image

1
2

3

4
5

6

LIGHT-SW

FRONT-SW

BACK-SW

1
2

3

4
5

6

1
2

3

4
5

6

36,42,48,54 MODELS

TWO LAMPHOLDERS

ONE LAMPHOLDER

18,24,30 MODELS

60,66,72 MODELS

THREE LAMPHOLDERS

F-T'STAT

B-T'STAT

ELEMENT

ELEMENT

GR

N

L1

LN

4

3

2

1

5
7

9

10

8

11

13

14

15

15
15

15

A-L1
A-LN

B-L1

C-L1

FOR REMOTE MODELS

LABEL LEAD WIRES AS SHOWN.

LEADS TO BE 6" FROM HOUSING

FDDLB-120V

WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.

WIRE # 1 TO BE 12 GA. - 100°C.

ALL OTHER WIRES TO BE 12 GA. - 250°C.

3

7

8

6

12

16

17

18

16

1
2

3

4
5

6

FRONT-SW

BACK-SW

1
2

3

4
5

6

F-T'STAT

B-T'STAT

ELEMENT

ELEMENT

GR

N

L1

L2

4

3

2

1

5

6

7

8

9

10

13

12

11

A-L1
A-L2

B-L1

B-L2

FOR REMOTE MODELS

LABEL LEAD WIRES AS SHOWN.

LEADS TO BE 6" FROM HOUSING

FDDB-208/240V

WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.

WIRE # 1 TO BE 12 GA. - 100°C.

ALL OTHER WIRES TO BE 12 GA. - 250°C.

FDDB-208/240V WIRING DIAGRAM

FDDLB-120V WIRING DIAGRAM

9

G.

H.