9. WIRING DIAGRAMS
1
2
3
4
5
6
FRONT-SW
F-T'STAT
ELEMENT
GR
N
L1
LN
4
3
2
1
5 A-L1
A-LN
FOR REMOTE MODELS
LABEL LEAD WIRES AS SHOWN.
LEADS TO BE 6" FROM HOUSING
FDB-120V
WIRE # 6 TO BE 10 GA. - 450°C.
WIRE # 1 TO BE 12 GA. - 100°C.
ALL OTHER WIRES TO BE 12 GA. - 200 OR 250°C.
6
7
1
2
3
4
5
6
FRONT-SW
F-T'STAT
ELEMENT
GR
N
L1
L2
4
3
2
1
5
6
7
A-L1
A-L2
FOR REMOTE MODELS
LABEL LEAD WIRES AS SHOWN.
LEADS TO BE 6" FROM HOUSING
FDC-208/240V
WIRE # 6 TO BE 10 GA. - 450°C.
WIRE # 1 TO BE 12 GA. - 100°C.
ALL OTHER WIRES TO BE 12 GA. - 200 OR 250°C.
FDB-120V WIRING DIAGRAM
FDB-208/240V WIRING DIAGRAM
6
A.
B.