9. WIRING DIAGRAMS

1
2

3

4
5

6

FRONT-SW

F-T'STAT

ELEMENT

GR

N

L1

LN

4

3

2

1

5 A-L1

A-LN

FOR REMOTE MODELS

LABEL LEAD WIRES AS SHOWN.

LEADS TO BE 6" FROM HOUSING

FDB-120V

WIRE # 6 TO BE 10 GA. - 450°C.

WIRE # 1 TO BE 12 GA. - 100°C.

ALL OTHER WIRES TO BE 12 GA. - 200 OR 250°C.

6

7

1
2

3

4
5

6

FRONT-SW

F-T'STAT

ELEMENT

GR

N

L1

L2

4

3

2

1

5

6

7

A-L1
A-L2

FOR REMOTE MODELS

LABEL LEAD WIRES AS SHOWN.

LEADS TO BE 6" FROM HOUSING

FDC-208/240V

WIRE # 6 TO BE 10 GA. - 450°C.

WIRE # 1 TO BE 12 GA. - 100°C.

ALL OTHER WIRES TO BE 12 GA. - 200 OR 250°C.

FDB-120V WIRING DIAGRAM

FDB-208/240V WIRING DIAGRAM

6

A.

B.