beautypg.com

Taking into operation – Pfannenberg PYRA PY X-S-05 Series User Manual

Page 4

background image

085 501 949j

30320-004j

4

Taking into operation

Safety notes:
- Installation must be carried out by an electrician in compliance with the latest codes and regulations.
- Danger: High voltage may be present.
- Prior to opening, it must be ensured that no voltage is applied to the device.
- Before electrical connection, the supply voltage on the type plate is to be checked. The wrong operating voltage can

lead to damages or to the destruction of the equipment.

- During installation it must be ensured that the connection cables are secured against tension and distortion.

Please observe: The devices are not designed for portable use.

- CAUTION: When making installation, route field wiring away from sharp projections, corners and internal

components.

- The function of the unit is only guaranteed if the upper and lower section is joined correctly.
- In order to prevent detriment to sight, continuously looking directly in the activated light is to be avoided.

Opening the housing

Closing the housing

3/8

1.

2.

3/8

1.

2.

The unit is not closed when delivered.
Sealing plugs for the housing screws are available as accessories.

Electrical connection:





Connecting cables:

7 [0.28"]

7 [0.28"]

solid

stranded

Option –SSM (Soft-Start-Module) (24V DC only):

- Limiting of the switch-on current peak to max. 2.1A
- Connection of the operating voltage to the equipment starts at >7V
- Resistance for the line monitoring connected.
Operating voltage range: 18V – 30V DC

Connection of a resistor
for line monitoring:








Cable gland entries
To guarantee the specified protection type,
cable grommets with a protection type of IP 66
are to be installed at the openings provided for
this purpose. The supplied diaphragm nipple
can be replaced with a cable gland or with an
M12 plug connection with a flange
measurement of M20.

Maintenance, Service and Ordering Spare Parts
The device does not require any special maintenance. External cleaning should be done with a mild soap solution
without the use of solvents. The device may only be operated in the undamaged state within the specified rating.
Conversions, alterations, improper and inadmissible use as well as the non-observance of the notes in these
operating instructions shall render the warranty null and void.
Components may be replaced only by original spare parts. As a matter of principle, repairs are to be carried out in the
manufacturing works.

Circuit board for electrical
connection (located in the
base section):

By loosing the four cover
screws, the upper section
can be removed.

The housing is closed by
turning the cover screws to
the limit position until the
housing locks into place.

N

L

+

Connection for
Operating voltage

the remaining membrane break-out.

After pushing through the cable remove

Diaphragm nipple IP 66

(provided)

(for low voltage versions)

M12 plug connector IP 66

Cable gland IP 66

Position of resistor in last device when using several beacons in parallel

Resistor for line monitoring (1KOhm) at terminal for operating voltage

X1

Remove resistors that are not needed