30320-004j

3

PY X-S-05 – Beacon

Operating and installation instruction

Dimensions

Ø

6.

3

[0

.2

5]

22 [0.87"]

80.6 [3.17]

109.6 [4.31]

98 [3.86]

86

[3

,3

85

]

prepared
M20 piercing

37 [1.46"]

Technical Data

Flash energy

5J

Rated effective luminous
intensity

44 cd (clear)

Flash frequency

1Hz

Rated voltage

12 V DC

24V DC

48V DC

24V AC

50/60 Hz

115 V AC, 50/60

Hz

230V AC
50/60 Hz

Operating voltage range

10 –15 V DC

18 – 30 V DC

40 – 57 V DC

18 – 30 V AC

95 - 127

V AC

195 – 253 V AC

Current consumption
(max)

700 mA

360 mA

170 mA

800 mA

120 mA

90mA

Power consumption

7,5 W

9,5 W

7,5 W

30 VA

14,5 VA

21,5 VA

Duty cycle

100%

Connection terminal

0,14 - 2,5mm² / AWG24 - AWG 14 (stranded)

Protection system

IP66 (EN60529), Type 4 & 4x

Protection class

II

Double insulated equipment

Operating temperature

-40°C…+55°C

Storage temperature

-40°C…+70°C

Max. rel. Humidity

90%

Cable entry

4x M20 (prepared)

Sealing range of
grommet

7 – 13 mm

With the use of cable diameters <7 mm, a cable screw joint

with sufficient ingress protection must be provided

Material of housing

PC/ABS Blend

Material of lens

PC

Installation position

arbitrary

Options

-SSM (see page 4)

Accessory

Sealing plug (Art-no. 28300000002)

Lens colours

clear, white, yellow, amber, red, green, blue

Approvals

Approvals

(valid for marked equipment)

Construction Product
Directive

(89/106/EWG)

VdS 0786-CPD-21219

Options

–SSM (24V DC only)

Rated voltage

24V DC

48V DC

Operating voltage range
acc. to EN54-23

18V – 30V

40 – 57V DC

Lens colours

red, clear

Signalling area

EN 54-23 Category O: see document 30320-005-1

Environmental
protection class

Type B

Installation position

see document 30303-005-1

The test was performed using the provided diaphragm nipples and the outer fixing holes.

VdS

G212186, data see Construction Product Directive (89/106/EWG)

GL

61062-13 HH Environmental Category C, H, EMC1
Rated Voltage

Visual Signal Appliance - General Signaling Equipment - UEES, UEES7

UL, cUL

115V AC
230V AC
24V AC
12V DC
24V DC
48V DC

Suitable for indoor and outdoor use.
Warning: Not to be used as a Visual Public Mode Alarm Notification Appliance.

According to CSA-C22.2 No. 205-M1983 clause 4.3.4 the connection is limited to max.
three leads.

PYRA Xenon beacons PY X-S-05 comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules

Content of package:
1x Alarm device
1x Diaphragm nipple M20
1x Operating instruction
1x Resistor (only –SSM)

44.1 [1.74"]

35.4

[1.39"]

25

.3

[1

"]

13

[0

.5

1"

]

50 [1.97"]

26.8 [1.06"]

35

.4

[1

.3

9"

]

60

[2

.3

6"

]

Hole pattern in the

inside of housing