Approvals

Approvals

(

valid for marked equipment)

Construction Product

Directive

(89/106/EWG)

VdS 0786-CPD-xxxxx

(in preparation)

Options

–SSM

Rated voltage

24V DC

Rated voltage range acc. to

EN54-3, EN54-23

18V – 57V

Option: -SSM: 18V – 30V

Tone

2

15

60

104

131

146

Compliant with the Construction Product Directive (89/106/EWG)

1200Hz-500Hz (Saw tooth) DIN/PFEER P.T.A.P.

500Hz-1200Hz (Slow whoop)

825Hz (Continuous)

660Hz (Intermittent tone)

800Hz/ 1000Hz (Alternating tone)

544Hz/ 440Hz (NF S 32-001)

Signaling area

EN54-3: see document 30304-005-1

Environmental

protection class

Type B (T

amb

-25°C…+55°C)

VdS

Gxxxxx, data see Construction Product Directive (89/106/EWG) (in preparation)

GL

GLxxxxx (in preparation)

Environmental Category C, H, EMC1
In preparation: UCST, UCST7, UEES, UEES7

(only 24V DC): ULSZ, ULSZ7

Rated

voltage

Fire Alarm Equipment

General Signal Equipment

PA 5

12 – 48V DC

24V AC

115V AC

230V AC

X

Special application limited voltage

range 18 – 57V DC

X

UL, cUL

PA X 5-05

PA X 5-10

12V DC

24V DC

48V DC

24V AC

115V AC

230V AC

X

UL specifications:

Suitable for indoor and outdoor use.

Signaling area: see document 30304-005-1

Cable gland entries:
Conduit installation needs to be UL/ cUL listed fittings suitable for knockout openings. The supply wiring has to be en-

closed in metal conduits for products for Fire Alarm Use.

According to CSA-C22.2 No. 205-M1983 clause 4.3.4 the connection is limited to max. seven leads for combined units

(PA X).

Installation:

The units shall be installed indoors or outdoors in accordance with the manufacturer’s installation instructions as well as

the National Electrical Code (NFPA 70) and the National Fire Alarm Code (NFPA 72) for the units evaluated for Public
Fire Alarm applications in the U.S. In Canada, they shall be installed in accordance with the Canadian Electrical Code,

Part 1 and the Standard for the Installation of Fire Alarm Systems CAN/ULC-S524-M91 for the units evaluated for Public

Fire Alarm applications. The installation shall also be in a manner acceptable with the local authority having jurisdiction.


For audible application for Fire Alarm Service use both terminals for connection. Break wire run to provide Electrical

Supervision (see UL 464 clause 39.1e). The tone no. 111 is to be used for evacuation use only (see UL 464 clause

39.1e)