beautypg.com

Appendix b, Degraded raid array – MSI Z97 GAMING 9 AC Manual User Manual

Page 108

background image

Appendix B

B-10

Intel RAID

Degraded RAID Array

A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard

drive members fails or is temporarily disconnected, and data mirroring is lost. As a

result, the system can only utilize the remaining functional hard drive member. To

re-establish data mirroring and restore data redundancy, refer to the procedure below

that corresponds to the current situation.

Missing Hard Drive Member

Make sure the system is powered off.
Reconnect the hard drive.
Reboot the system to Windows; the rebuild will occur automatically.

Failed Hard Drive Member

Make sure the system is powered off.
Replace the failed hard drive with a new one that is of equal or greater capacity.
Reboot the system to Intel RAID Option ROM by press and keys

simultaneously during the Power-On Self Test (POST).

1.
2.
3.

1.
2.
3.

Select the port of the destination disk for rebuilding, and then press ENTER.

4.

RAID Volumes
ID Name Level Strip Size Status Bootable
0 Volume0 RAID 1(Mirror) N/A XXX.XGB

Degraded Yes

Physical Disks:
Port Device Model

Serial #

Size

Type/Status(Vol ID)

1 XXXXXXXXXXXXX XXXXXXXXXXXXX

XXX.XGB

Member Disk (0)

2 XXXXXXXXXXXXX XXXXXXXXXXXXX

XXX.XGB

Member Disk (0)

Press to enter Configuration Utility..

DISK / VOLUME INFORMATION

[ ]

4. Recovery Volume Options
4. Recovery Volume Options

5. Exit

RAID Volumes :

None defined.

Physical Devices :
Port Device Model Serial # Size Type/Status (Vol ID)

1 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB

Non-RAID Disk

2 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB

Non-RAID Disk

[ ↑↓] - Select [ESC] - Exit [ENTER] - Select Menu

1. Create RAID Volume
2. Delete RAID Volume

“Degraded” volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.

[ ]

DEGRADED VOLUME DETECTED

Select the port of the destination disk for rebuilding (ESC to exit):

[ ↑↓] - Previous/ Next [ENTER] - Select [ESC] - Exit

Port Drive Model

Serial #

Size

1 XXXX-XXXXXXXX

XXXXXXXXXXXXXX XXX.XGB

[ ]

MAIN MENU

This manual is related to the following products: