Duff-Norton SK6415-200 (SPA Series AC) User Manual
Page 3
1-1.
GENERAL
This manual provides instructions for the installation,
operation and maintenance of the Duff-Norton 6415 &
7415 Series AC actuator. It includes proper procedures
for the disassembly, cleaning, inspection, rebuilding and
assembly of the actuator. To ensure efficient, long,
satisfactory use of this unit, these instructions should be
followed closely.
1-2.
INDUSTRIAL USE ONLY
The actuators described and illustrated in this manual
are intended for industrial use only and should not be
used to lift, support or otherwise transport people,
unless you have a written statement from Duff-Norton
Company which authorizes this actuator unit, as used in
your application, as suitable for moving people.
1-3.
FACTORY PREPARATION
Each actuator is carefully assembled and tested at the
factory to ensure that the motor and the mechanical
components will function properly and that the actuator
will lift its rated load.
The brake is preset at the factory and no further
adjustment is required. With proper maintenance, this
brake prevents the actuator from self-lowering.
The actuator is pre-lubricated at the factory and thus
requires minimum maintenance.
Limit switches are checked at the factory for proper
functioning.
External wires are provided for customer
hookup. Wires are color coded as to direction of travel of
the actuator (see wiring diagram, Figure 6.2).
1-4. SPECIFICATIONS
TABLE 1-4.
1-5.
WARRANTY AND WARRANTY REPAIR
Subject to the conditions stated herein, Duff-Norton will
repair or replace, without charge, any parts proven to
Duff-Norton's satisfaction to have been defective in
material and workmanship. Claims must be made within
one year after date of shipment. Duff-Norton will not
repair or replace any parts that become inoperative
because of improper maintenance, eccentric loading,
overloading, chemical or abrasive action, excessive heat,
or other abuse.
Equipment and accessories not of Duff-Norton's
manufacture are warranted only to the extent that they
are warranted by their manufacturer, and only if the
claimed defect arose during normal use, applications
and service. Equipment which has been altered or
modified by anyone without Duff-Norton's authorization
is not warranted by Duff-Norton. EXCEPT AS STATED
HEREIN, DUFF-NORTON MAKES NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE.
If you have any questions concerning warranty
repair, please contact the Duff-Norton Company.
Authorization for return must be received from
the Duff-Norton Company before returning any
equipment for inspection or warranty repair.
SECTION 1
GENERAL INFORMATION
3
Applied
Standard
Standard
Standard
Standard
Load
115 Volt
220 Volt
115 Volt
220 Volt
(lbs.)
Motor
Motor
Motor
Motor
(60 Hz)
(50 Hz)
(60 Hz)
(50 Hz)
500
52
44
5.00
1.70
1000
51
42
5.50
1.70
1500
50
41
6.20
2.00
Amps
Speed
(in/min)
6415-200 manual 10/10/06 11:46 AM Page 3