1-1.

GENERAL

This manual provides instructions for the installation,

operation and maintenance of the Duff-Norton 6415 &

7415 Series AC actuator. It includes proper procedures

for the disassembly, cleaning, inspection, rebuilding and

assembly of the actuator. To ensure efficient, long,

satisfactory use of this unit, these instructions should be

followed closely.

1-2.

INDUSTRIAL USE ONLY

The actuators described and illustrated in this manual

are intended for industrial use only and should not be

used to lift, support or otherwise transport people,

unless you have a written statement from Duff-Norton

Company which authorizes this actuator unit, as used in

your application, as suitable for moving people.

1-3.

FACTORY PREPARATION

Each actuator is carefully assembled and tested at the

factory to ensure that the motor and the mechanical

components will function properly and that the actuator

will lift its rated load.

The brake is preset at the factory and no further

adjustment is required. With proper maintenance, this

brake prevents the actuator from self-lowering.

The actuator is pre-lubricated at the factory and thus

requires minimum maintenance.

Limit switches are checked at the factory for proper

functioning.

External wires are provided for customer

hookup. Wires are color coded as to direction of travel of

the actuator (see wiring diagram, Figure 6.2).

1-4. SPECIFICATIONS
TABLE 1-4.

1-5.

WARRANTY AND WARRANTY REPAIR

Subject to the conditions stated herein, Duff-Norton will

repair or replace, without charge, any parts proven to

Duff-Norton's satisfaction to have been defective in

material and workmanship. Claims must be made within

one year after date of shipment. Duff-Norton will not

repair or replace any parts that become inoperative

because of improper maintenance, eccentric loading,

overloading, chemical or abrasive action, excessive heat,

or other abuse.

Equipment and accessories not of Duff-Norton's

manufacture are warranted only to the extent that they

are warranted by their manufacturer, and only if the

claimed defect arose during normal use, applications

and service. Equipment which has been altered or

modified by anyone without Duff-Norton's authorization

is not warranted by Duff-Norton. EXCEPT AS STATED

HEREIN, DUFF-NORTON MAKES NO OTHER

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING

WARRANTIES OF MERCHANTABILITY AND FITNESS

FOR A PARTICULAR PURPOSE.

If you have any questions concerning warranty

repair, please contact the Duff-Norton Company.

Authorization for return must be received from

the Duff-Norton Company before returning any

equipment for inspection or warranty repair.

SECTION 1

GENERAL INFORMATION

3

Applied

Standard

Standard

Standard

Standard

Load

115 Volt

220 Volt

115 Volt

220 Volt

(lbs.)

Motor

Motor

Motor

Motor

(60 Hz)

(50 Hz)

(60 Hz)

(50 Hz)

500

52

44

5.00

1.70

1000

51

42

5.50

1.70

1500

50

41

6.20

2.00

Amps

Speed

(in/min)

6415-200 manual 10/10/06 11:46 AM Page 3