WIKA operating instructions models 73, 74, 75

6. Commissioning, operation

When screwing the gauges in, the force required to do this must not

be applied through the casing, but only through the spanner flats

provided for this purpose and using a suitable tool.

6. Commissioning, operation

Installation with

spanner

If possible, the entire length of the stem should be exposed to the

temperature being measured. However, at least the length of the

active part that corresponds to the length of the gas expansion

vessel (active length).

In pipelines or other measuring points, the temperature probe must

be angled as far towards the flow as possible.

Errors in thermal conduction occur if the area where the

temperature is to be measured is so small, that the mass of the

temperature probe acts as thermal capacity. Errors in thermal

conduction may also occur if the immersion depth is insufficient, if

the mounting fittings are connected to a good thermal conductor

(metal plate or similar) and there is a considerable difference

in temperature between the measuring and mounting element

temperatures.

Mount the dial casing free from vibration. If necessary, it is possible

to isolate the instrument from the mounting point by installing

a flexible connection line between the measuring point and the

thermometer and mounting the instrument on a suitable bracket.