beautypg.com

Design and function, Specifications / 4. design and function – WIKA LS-10 User Manual

Page 9

background image

9

WIKA operating instructions submersible pressure transmitter, model LS-10

14075012.01 08/2013 GB/D/F/E

GB

Analogue signal

4 ... 20 mA

Power supply

DC 10 ... 30 V

Ingress protection (per IEC 60529)

IP 68

Permissible temperature ranges

Medium: -10 ... +50 °C

Ambient: -10 ... +50 °C

Storage: -30 ... +80 °C

Immersion depth

up to 100 m

CE conformity

EMC directive 2004/108/EC, EN 61326 emission

(group 1, class B) and immunity (industrial application)

For special model numbers, e.g. LS-10000, please note the specifications stated on the delivery note.

For further specifications see WIKA data sheet PE 81.55 and the order documentation.

4. Design and function

4.1 Description

The prevailing pressure is measured at the sensor element through the deformation of a diaphragm. By supplying

power, this deformation of the diaphragm is converted into an electrical signal. The output signal from the pressure

transmitter is amplified and proportional to the prevailing pressure.

4.2 Scope of delivery

Cross-check scope of delivery with delivery note.