Diagram 2: Faceplate Attachment
Installation Directions
CL
Strike
4”
[101.60]
B
8”
[203.2]
CL Mortise
Door Prep
MORTISE LOCK
B
CORBIN/RUSSWIN
SARGENT (8200)
YALE (8800)
ARROW, FALCON
0"
BEST 34H-37H
1/4"
SCHLAGE
3 /4"
YALE (8700)
7/8"
BEST 45H & 47H
1/8"
Diagram 3: Determining Mortise Offset
To install the 310 series electric strike body to the
faceplate, install two #12-24 body mounting screws
as shown. Make sure bolts are tightened and secured.
Keeper position can be adjusted by loosening the #12-24
body mounting screws, and repositioning the strike body
as needed. Retighten body mounting screws after
adjustment is made