RealTime Display Indications
• When the DIONIC battery is being charged remaining runtime is
not displayed. 
 
• Remaining run time is calculated using the present available battery
capacity and a constantly updated accurate measurement of the 
present load on the battery. 
 
• If no load is detected, or if the battery is removed from the charger
before any discharge load is applied, the default assumed power for 
remaining run time calculations is 20 Watts. 
 
• When the battery determines that a load is attached, remaining run 
time will be calculated based on that load and the time remaining 
will be updated. 
 
• The battery will “learn” this new load and retain that load
information in non-volatile memory. If the battery is removed from 
the camera it will retain this information for 30 minutes or until it is 
returned to the charger or sees a new load. After 30 minutes the 
battery will return to the default load of 20 watts. 
•
OVERCURRENT INDICATION
If the DIONIC 90 battery is
subjected to a load that exceeds specifications, the protection 
electronics will operate to protect the lithium ion cells. All status 
icons on the LCD will flash at a once per second rate. This can 
occur, for example, if a cold halogen light =/>75 watts is turned on. 
When the over-load condition is removed, the display will return to 
normal. 