5. Place shaft in a soft-jawed vise. If soft-jawed

vise is not available, use a bit of cloth, wood or
gasket material to hold the shaft in place without
marking or deforming it. Use the end nips to
remove the key. Discard key after removal. (A
replacement is part of the kit.)

6. After removing key, pull rotor and shaft out of

housing. Set rotor/shaft and shielded bearing
housings aside.

7. Install sealed bearing housings by attaching the

Q-collar to the housing with the threaded inserts
for the attachment screws, rotor and shaft,
attachment screws, and then take the
replacement key and tap it into place in the drive
side keyway with the hammer.