beautypg.com

DOCTER DOCTER®classic 8x56 User Manual

Page 9

background image

9

Attention:

To provide for a fast retrieval of the graticule’s zero position when using different ammunition

or fillings, the graduated disk (10) can be turned such after loosening the cross-drive screw

(9) that both index marks (11) face each other.

The adjustment range for correcting the hit point is sufficiently dimensioned. Should, however

the graduation not suffice, we recommend you have your rifle with the rifle scope checked by

your gunsmith.

Setting the visual acuity

The visual acuity is adjusted by turning the rear eyepiece focussing knurl (2). A marksman’s

possible eye defect is then compensated when graticule and target image stand out sharply.

Eye defect compensation of ±2.5 dioptres is possible.


Estimating distances

The free space between the transverse bars of the graticules 1, 4, 5, 7 and 9 corresponds to

a width of 70cm on a target distance of 100 m, approximately the length of a roebuck. You

can therefore estimate distances by means of the graticule.

Option: Rifle scopes with illuminated graticule

All control and functional elements of the graticule illumination system except the graticule

itself are placed in a third dome on the centre tube of the rifle scope, similar to the vertical

and lateral adjustment. The power supply is provided by a lithium battery CR2032. Using the

rotary controller (12) the graticule illumination system is turned on or off and the luminous

intensity can be adjusted according to the brightness outdoors and to the individual

requirements of the marksman. The graticule illumination system is turned off when the point

marking (14) on the rotary controller faces the one on the centre tube (13).

To replace the lithium battery, the cover of the rotary controller has to be unscrewed by

turning it to the left. The lithium battery situated under the cover (15) can now be replaced.

Then the cover can be screwed together again with the rotary controller (12).

Accessories

To protect the outer parts of the instrument, interconnected protecting caps are delivered.

As a protection against lateral light, a telescopic rubber shade can be delivered on request,

which simultaneously guarantees the correct eye distance to the eyepiece and absorbs a

possible recoil.


Maintenance

When carefully operated, DOCTER® rifle scopes have a virtually unlimited life.

Before cleaning, the outer lens surfaces should be freed from dust (by means of a lens brush

or air bulb). This way, dirt particles and dust are prevented from being rubbed into the

blooming coat and damaging it. Abstain from using chemical solvents for cleaning the outer

lens surfaces!

In case of possible damage causing malfunction, the instrument must be sent to an

authorized repair shop.

This manual is related to the following products: